Kinetic Facades
Application Area

Kinetic Facades

Quiet, low-power linear and rotary actuator solutions for architectural kinetic facade systems, brise-soleil and dynamic shading applications.

Recommended Products
Use Cases

Where is it used in Kinetic Facades?

Common deployment scenarios with field-validated configurations.

01

Brise-Soleil Panels

Programmed angle changes for sun-control panels throughout the day.

02

Wing Facade Systems

Synchronised sets for opening/closing architectural wings.

03

Smart Windows and Vents

BMS-integrated automatic ventilation and shading.

04

Roof Window Opening

Models with backup batteries for atriums and smoke-evacuation systems.

Recommended Products

Best-fit series for Kinetic Facades

The Hedron product family deployed in this application with field-validated configurations.

HDR-26N

HDR-26N

From the Hedron portfolio: HDR-26N, 500N force class, 50-200mm stroke range.

  • Force: 500N
  • Stroke: 50-200mm
  • Speed: 11mm/s
HDR-35

HDR-35

From the Hedron portfolio: HDR-35, 2,300N force class, 50-400mm stroke range.

  • Force: 2,300N
  • Stroke: 50-400mm
  • Speed: 30mm/s
HDR-38

HDR-38

From the Hedron portfolio: HDR-38, 2,300N force class, 50-400mm stroke range.

  • Force: 2,300N
  • Stroke: 50-400mm
  • Speed: 30mm/s
HDR-52

HDR-52

From the Hedron portfolio: HDR-52, 6,000N force class, 50-400mm stroke range.

  • Force: 6,000N
  • Stroke: 50-400mm
  • Speed: 55mm/s
DJ825

DJ825

DJ825 linear actuator, 1,000/1,500/2,500N force, compact design, IP66.

  • Force: 1,000/1,500/2,500N
  • Stroke: ≤600 mm
  • Speed: 6-15 mm/s
DJ827

DJ827

From the Hedron portfolio: DJ827 Industrial.

  • Force: 500-6,000N
  • Stroke: ≤1,000 mm
  • Speed: 6-80 mm/s
Frequently Asked Questions

About the Kinetic Facades application

Short answers to the most common questions our project team receives. Request engineering support for your custom project.

What is the quiet operation class?
The facade series is designed to operate below 45 dB(A).
Is BMS integration possible?
KNX, BACnet and Modbus interfaces are provided through the control units.
Is it compliant with fire codes?
EN 12101-2 certified variants are available for smoke-evacuation applications.
Other Sectors

Other areas where Hedron solutions are deployed

Project Consulting

Talk to our engineering team for a custom Kinetic Facades solution.

We prepare technical recommendations and price quotes based on your load, stroke, environment and control architecture data.

0216 340 4120