Solar Tracking
Application Area

Solar Tracking

Long-life, low-maintenance linear actuator solutions for single-axis and dual-axis solar tracker configurations under outdoor conditions.

Recommended Products
Use Cases

Where is it used in Solar Tracking?

Common deployment scenarios with field-validated configurations.

01

Single-Axis Tracker

High-thrust, wide-stroke actuators for horizontal-axis tracking.

02

Dual-Axis Tracker

Synchronised sets for precise positioning on the azimuth and elevation axes.

03

CSP Reflector Steering

Mirror position control in concentrated solar power systems.

04

Solar Roof Steering

Panel-angle control for BIPV and custom building projects.

Recommended Products

Best-fit series for Solar Tracking

The Hedron product family deployed in this application with field-validated configurations.

DJ828

DJ828

DJ828 solar actuator, 15,000N dynamic / 45,000N static load, IP66, for solar tracking systems.

  • Force: 15,000N dinamik / 45,000N statik
  • Stroke: 500 / 700 / 1,000 mm (customizable)
  • Speed: 1.4 / 2 / 3 mm/s (selectable)
DJ817G

DJ817G

DJ817G solar actuator, 20,000N dynamic / 60,000N static load, IP65, -40℃ to +65℃.

  • Force: 20,000N dinamik / 60,000N statik
  • Stroke: 500-850 mm (optional)
  • Speed: ≥1.4 mm/s
DJ805H

DJ805H

DJ805H linear actuator, 3,500-17,000N high force, CAN bus and analogue control, IP67.

  • Force: 3,500-17,000N
  • Stroke: ≤1,000 mm
  • Speed: 6.5-35 mm/s
DJ805G

DJ805G

DJ805G linear actuator, 3,200-12,000N force, IP66/IP69K protection and multi-synchronous control.

  • Force: 3,200-12,000N
  • Stroke: ≤1,000 mm
  • Speed: 6.0-37 mm/s
DJ816

DJ816

DJ816 solar actuator, ≥6,000N force, IP66, for solar panel angle adjustment.

  • Force: ≥6,000N
  • Stroke: 500 / 700 / 1,000 mm (customizable)
  • Speed: 1.5 / 2 / 3 mm/s (customizable)
DJ865

DJ865

DJ865 solar actuator, 30,000N dynamic / 50,000N static load, IP66.

  • Force: 30,000N dinamik / 50,000N statik
  • Stroke: 1,000 mm
  • Speed: 1.5 mm/s
DJ817K

DJ817K

DJ817K solar actuator, 25,000N dynamic / 60,000N static load, 30-year design life.

  • Force: 25,000N dinamik / 60,000N statik
  • Stroke: 300-900 mm
  • Speed: 1.0 mm/s
DJ833T

DJ833T

DJ833T solar actuator, 22,500N dynamic / 133,000N static load, IP65.

  • Force: 22,500N dinamik / 133,000N statik
  • Stroke: 500-1,000 mm (optional)
  • Speed: ≥0.7 mm/s
Frequently Asked Questions

About the Solar Tracking application

Short answers to the most common questions our project team receives. Request engineering support for your custom project.

Which IP class is needed outdoors?
IP66 minimum for solar tracker applications; IP67+ models that have passed salt-spray testing are recommended for coastal/desert environments.
What is the operating temperature range?
The solar series delivers nominal performance from -30°C to +75°C; an optional kit extends this to -40°C.
How is wind load capacity calculated?
Maximum static load is validated at 1.5× the push/pull force; a project-based load report is provided.
Can cable length be customised?
Standard 2 m, 5 m and 10 m options plus project-specific custom lengths are available.
Other Sectors

Other areas where Hedron solutions are deployed

Project Consulting

Talk to our engineering team for a custom Solar Tracking solution.

We prepare technical recommendations and price quotes based on your load, stroke, environment and control architecture data.

0216 340 4120